Quick answer
For a straight residential flight, the 2021 IRC R311.7.5 sets a maximum 7¾-inch riser and a minimum 10-inch tread. Check built variation within the flight against the ⅜-inch limit. The AWC DCA 6 deck detail separately shows a 5-inch minimum throat for its cut stringers. Verify the locally adopted edition and details.
Project tool checklist
- Framing square
- Stair gauges
- 25-foot tape measure
- Pencil
Quick reference table
Standard drop mount, 10.5-inch tread and the automatic riser count, with no waste added. Stock uses even-foot lengths with an 8-foot minimum. Check the finished layout, supports and end cuts independently.
| Rise (in) | Risers | Treads | Unit rise (in) | Run (in) | 2×12 stock (ft) |
|---|---|---|---|---|---|
| 24 | 3 | 2 | 8 | 21 | 8 |
| 30 | 4 | 3 | 7.5 | 31.5 | 8 |
| 36 | 5 | 4 | 7.2 | 42 | 8 |
| 42 | 6 | 5 | 7 | 52.5 | 8 |
| 48 | 7 | 6 | 6.86 | 63 | 8 |
| 54 | 7 | 6 | 7.71 | 63 | 8 |
| 60 | 8 | 7 | 7.5 | 73.5 | 8 |
| 72 | 10 | 9 | 7.2 | 94.5 | 10 |
| 96 | 13 | 12 | 7.38 | 126 | 14 |
How to use the Stair Stringer Calculator
- Measure finished landing to finished landing vertically. Record clear stair width, tread run and mounting arrangement, including the thickness of final flooring.
- Choose your units, enter the measured dimensions, and review the live drawing. Set a waste allowance and enter local prices.
- Review the riser and tread checks, then compare throat, span, connections and supports with the approved stair detail before selecting stock.
Formula & engineering reference
Riser height r = total rise ÷ riser count. In a drop mount, treads = risers − 1. Total run = treads × tread depth T. The floor-to-floor diagonal is √(rise² + run²). With an 11.25-inch blank, modeled throat = 11.25 − rT ÷ √(r² + T²).
Project questions
How many risers fit a 36-inch total rise?
Five equal risers give 7.20 inches per riser. A drop-mounted flight has four treads and a 42-inch total run at a tread depth of 10.5 inches.
What does the throat measurement represent?
It is the wood remaining beneath the deepest notch measured perpendicular to the stringer edge. A 3½-inch screening flag is separate from the 5-inch cut-stringer detail in AWC DCA 6.
Is the 2R + T comfort band an IRC requirement?
It is a proportion check for stride comfort. The code dimensions, field uniformity and applicable structural details require separate checks.
How is a drop mount different from a flush mount?
In the modeled drop mount the upper landing serves as the final walking surface, so the flight has one fewer tread than risers. The flush option counts a top tread on the stringer.
Do equal calculated risers prove the finished stair is uniform?
Verify each finished step in the field. The upper landing, tread material, bottom cut and landing surface can all change the actual first or last riser.